A-Permits Reference Number - 76491



Inspection Record Number
Inspection Record Number 1
Inspection Date: 06/11/2019
Inspector: Dennis Kiley
Inspection Type: PRELIMINARY
Inspection Hours: 1.0
Record Date: 06/11/2019
Record Entered By: Dennis Kiley
Inspection Comments: Per direction Permitee obtained tree removal permit, removed tree and started work. Grade and forms not ready. Driveway width does not match permit, no CMB under gutter forms, 12” of CMB at driveway, no CMB compacted on site, curb drain pipe is ABS. Per last visit I discussed driveway apron repai with next door neighbor; this visit I marked out removals of neighbors driveway apron due to severe tree damage and grade difference. I directed Permitee Hatham to obtain written agreement with neighbor for apron concrete repair and/or provide driveway access at all times via steel plate. Call for grade and form reinspection.
Inspection Record Number 2
Inspection Date: 06/14/2019
Inspector: Dennis Kiley
Inspection Type: PRELIMINARY
Inspection Hours: 1.0
Record Date: 06/14/2019
Record Entered By: Dennis Kiley
Inspection Comments: Permitee directed to lower sidewalk form closest to street 1” below level from back form to create cross slope in sidewalk. After correction ok to place concrete.
Inspection Record Number 3
Inspection Date: 06/21/2019
Inspector: Dennis Kiley
Inspection Type: FINAL
Inspection Hours: 1.0
Record Date: 06/21/2019
Record Entered By: Dennis Kiley
Inspection Comments: Work completed. Final.